Climacom

Banner AY en
Banner AY mobile

Mitsubishi Electric MSZ-AY Inverter Air Conditioner – Quiet and Powerful Performance

AY Inverter – High Performance and Energy Efficiency

The MSZ-AY series offers the optimal balance between performance and energy efficiency. The model features a new, more stylish design, heating capability at temperatures down to -20°C, a high energy rating of A+++ (for sizes 25/35), exceptionally quiet operation, and a built-in V-Blocking filter for air purification.

Exceptionally Quiet Operation

In addition to the many advantages of the model, a noise level of only 18 dBA has been achieved for sizes 25/35 (single split).

Luxury Matte Finish for Easy Cleaning

The elegant design and delicate matte finish of the indoor unit allow for easier cleaning. The compact design with rounded edges makes the new series suitable for any room.

Cleaner Air

 Air purification in the room is achieved through the advanced V-Blocking filter, which neutralizes bacteria, viruses, allergens, dust, and mold.

MSZ AY 1

Night Mode Function

By activating Night Mode via the wireless remote control, your air conditioner automatically adjusts for a calm and quiet evening:

Soft Light – the indicator lamp dims to avoid disturbing your sleep.
Silence – sound signals are deactivated for maximum tranquility.
Quieter Outdoor Unit – operating noise is reduced by 3 dB, allowing you to enjoy silence throughout the night.

MSZ AY 2

Control at Your Fingertips

Have you ever wished to control the temperature in your home without even getting up from the couch? Have you wanted to arrive at a pre-heated home in winter or a cooled space during hot summer days?
All of this is possible with the Mitsubishi Electric Wi-Fi adapter!

Self-cleaning mode

High humidity inside the air conditioner causes mold and unpleasant odors. After the air conditioner stops operating, an automatic airflow dries the interior to keep it clean.

1

High humidity inside the air conditioner causes mold and unpleasant odors.

2

The airflow mode effectively suppresses mold growth and keeps the air fresh and clean.

3

Maintains the cleanliness of the unit’s interior.

Low noise
Low noise
Extremely quiet operation of the indoor unit.
Operation Lock – indoor unit
Operation Lock – indoor unit
To accommodate specific operating requirements, the heating or cooling mode can be set via the control panel on the outdoor unit.
Energy efficiency class A+++
Energy efficiency class A+++
Energy efficiency class A++
Energy efficiency class A++
Self Clean Mode
Self Clean Mode
When Self Clean Mode is activated, fan operation starts after cooling/dry mode. This operation helps to dry inside indoor unit to prevent molds and odors. You can feel the clean air without frequent cleaning by yourself.
Econo cool -E; -ET; -ER Only
Econo cool -E; -ET; -ER Only
Econo Cool is an intelligent temperature control feature that adjusts the amount of airflow to the body based on the temperature of the outlet air. The temperature setting can be increased by 2°C without any loss of comfort, therefore achieving a 20% increase in energy efficiency.
MXZ connection (multisplit)
MXZ connection (multisplit)
It is possible to connect to an outdoor unit from the MXZ series (multi-split system).
Night mode
Night mode
The temperature self-regulates according to sleeping habits.
10°C Heating
10°C Heating
In the heating process, the temperature can be set to increase gradually from 1°C to 10°C.
ACO
ACO
The air conditioner automatically switches from heating mode to cooling mode and vice versa to maintain the desired temperature.
Cleaning-free Pipe Reuse
Cleaning-free Pipe Reuse
Allows the use of the same pipes, as well as easy replacement of air conditioning systems using R22 or R410 refrigerant.
DC Fan Motor
DC Fan Motor
A high efficiency DC motor drives the outdoor unit fan. The efficiency is much higher than the equivalent AC motor.
Joint Lap DC Мотор
Joint Lap DC Мотор
Joint Lap DC Мотор Mitsubishi Electric's unique motor, which in Japan is called the Poki Poki Motor. With its high density, it contributes to significantly high efficiency.
M-NET Connection
M-NET Connection
M-NET Connection The air conditioners can be connected to a MELANS system controller (M-NET controller).
On/Off Timer
On/Off Timer
Use the remote control to set the on and off times of the air conditioner.
V Blocking Filter
V Blocking Filter
With an antiviral effect, it retains 99% of the adhering virus and other harmful substances, such as bacteria, mold and allergens. The double-layer non-woven fabric filter and electrostatic filter can effectively capture and remove small particles from the air in your room.
WiFi interface
WiFi interface
The WiFi interface provides remote control of the air conditioning system using smartphones, tablets or laptops.
Automatic ventilation mode
Automatic ventilation mode
The airflow strength setting automatically adjusts the ventilation speed of the indoor unit according to the temperature conditions in the room.
Automatic closing of the slat
Automatic closing of the slat
The louver of the air conditioner closes automatically when the body is not in working mode, giving an aesthetic appearance.
Automatic restart
Automatic restart
Extremely useful during power outages. When it recovers, the air conditioner turns on automatically.
Built-in
Built-in "Weekly Timer" Function
Easy setting of the desired temperature and the time of turning on and off the air conditioner in accordance with your lifestyle. Limit energy waste by using the timer to prevent the air conditioner from running excessively in case you forget to turn it off.
Double-layer
Double-layer
Double-layer coating that prevents hydrophobic and hydrophilic dirt from sticking to the inner surface and inner parts of the indoor unit.
Remote control with backlight
Remote control with backlight
The remote control screen is LED-backlit, so you could check the settings even when the room is dark.
Ribbed pipes
Ribbed pipes
High efficiency finned tubes are used in heat exchangers to increase the heat exchange area.
Cooling to low temperatures
Cooling to low temperatures
Intelligent control of the ventilation power of the outdoor unit ensures optimal performance even when the outdoor temperature is low.
PAM control
PAM control
PAM is a technology that controls the sinusoidal shape of the current to match that of the voltage. In this way, efficient use of the input power is achieved. Using PAM control, 98% of the consumed power is used efficiently.
Purifying filter
Purifying filter
The filter has a large catching surface and aromatizes the circulating air.
Mode
Mode "i save"
“i save” is a simple function that restores the previous temperature setting of the air conditioner by pressing only one button on the remote control. Press the same button twice again to immediately return to the previous setting. This function contributes to comfortable and economical use by reducing the excess consumption of electricity when, for example, you leave the room or during sleep.
Mode of vertical swing of the slat
Mode of vertical swing of the slat
The exhaust fan "swings" from end to end so that the air flow reaches every part of the room.
Mode of horizontal swing of the slat
Mode of horizontal swing of the slat
In this mode, the lamella of the air conditioner swings up and down, guaranteeing optimal air distribution in the room.
Circulation mode
Circulation mode
After reaching the set temperature in heating mode, the air conditioner automatically switches to Circulation mode, which mixes the warm air in the room.
Self-diagnosis
Self-diagnosis
Check codes are displayed on the remote control screen or operation indicator to inform the user of malfunctions that have occurred.
Connection with cones
Connection with cones
It is possible to connect to the cooling pipelines through cones.
System management of a group of air conditioners
System management of a group of air conditioners
One remote control is able to control the mode of operation of up to 16 cooling systems.
Control PAR-33MAA/PAC-YT52CRA
Control PAR-33MAA/PAC-YT52CRA
The air conditioners are compatible with a remote control type PAR-33MAA or PAC-YT52CRA, which has multiple control functions.
Error storage function
Error storage function
Refrigerant R32
Refrigerant R32

Blog articles you might like