Requirements for modern building technology are continuously increasing. Projects are becoming more complex, regulatory and technical requirements more stringent and detailed, and expectations more clearly defined. What is needed are not merely solutions that meet individual requirements, but integrated systems that open up new possibilities.
The new City Multi VRF YXM Series with R32 refrigerant has been developed to meet precisely these demands. It combines advanced developed technology, innovative safety management, and maximum flexibility within a system architecture that simplifies system design and ensures reliable implementation. As a result, this new generation is suited to both demanding commercial buildings and modern architectural projects with individual requirements.
Hotels, schools
Office buildings, hospitals
Commercial premises
Multifunctional buildings
Noise optimization at a new level
The noise optimization of the YXM series is based on a complete redesign of the fan. The newly developed fan blades reduce airflow interference, improve air transfer, and enable quieter, more efficient operation. The Low-Noise mode can be configured in four stages: 85%, 70%, 60%, and 50% of the rated fan speed. This allows noise levels to be flexibly adjusted to different requirements – making the system particularly suitable for residential areas and noise-sensitive environments.
Optimized fan
VFT heat exchanger for high efficiency
The new patented VFT heat exchanger is designed for higher efficiency and more reliable operation. The flat aluminum tubes ensure uniform refrigerant distribution, while the increased heat transfer surface area contributes to reduced energy consumption in both cooling and heating operation.
The segmented design allows individual sections of the heat exchanger to be activated according to the current load. This enables the system to operate more efficiently across different operating modes and conditions.
The smooth fins limit the accumulation of dirt, and the drainage slots support rapid water removal and more efficient defrosting. The anti-corrosion coating contributes to a long service life and reliable operation under more demanding conditions.
Key features
New patented vertical flat tube (VFT) heat exchanger
Increased heat transfer efficiency through optimized refrigerant distribution
Improved drainage during defrosting enabled by angled fins
High heating capacity at
very low outdoor temperatures
Even at extremely low temperatures, the YXM series maintains high performance. At an outdoor temperature of –10°C, the system provides up to 88% of the maximum heating capacity. This allows for the use of more compact outdoor units without compromising performance. An additional advantage is the flexibility in system design, including the possibility for long piping runs, while its robust construction is engineered to ensure reliable long-term operation.
Length of piping runs
Compared to the previous generation, which allowed a maximum vertical height difference of 90 m, the new YXM series allows for a height difference of up to 113 m. The maximum total length of the piping runs reaches 1,000 m. The guaranteed operating range of the systems in heating mode has also been expanded and is now from −25°C to 15.5°C.
City Multi VRF YXM - Y Series
The City Multi Y series offers a flexible VRF solution for heating or cooling all or only selected indoor units according to the building’s requirements.
The modular design of the outdoor units provides flexibility in system design and allows for application in open-plan offices, call centers, retail premises, and other large-scale buildings.
Key features and benefits:
Y series for cooling or heating.
Energy-efficient heat pump operation – effective heating or cooling with flexible system configuration.
R32 refrigerant with lower GWP – reduced environmental impact and compliance with future regulatory requirements.
Ultra-compact modular design – allows installation in space-constrained locations without compromising performance.
Wide compatibility with indoor units – supports various types and capacities for different applications.
Heating operation at outdoor temperatures as low as −25°C – reliable performance even under severe winter conditions.
Safety features with simplified maintenance – help reduce on-site servicing time and associated maintenance costs.
Low noise level – 5-stage mode for quieter operation.
Vertical height difference of up to 113 m – provides greater design flexibility for multi-storey and large-scale buildings.
City Multi VRF YXM - R2 Series
The City Multi R2 series provides simultaneous heating and cooling by redistributing excess heat between different zones in the building. The heat recovery technology enables energy savings of up to 30% compared to conventional heat pump systems.
The unique two-pipe system facilitates installation and maintenance, while providing exceptional flexibility in system design. It is suitable for hotels, offices, and other buildings with different requirements by zone.
Key benefits:
R2 series for simultaneous heating and cooling.
R32 refrigerant with lower GWP.
Compact modular design.
Wide compatibility with indoor units.
Patented VFT heat exchanger.
Reduced refrigerant charge.
Heating at outdoor temperatures down to –25°C.
Improved defrosting.
Five-stage low noise mode.
Vertical height difference up to 113 m.
Unique two-pipe system.
Safety when working with A2L refrigerants
The integrated safety management system of the YXM series ensures a high level of safety when operating with the refrigerant.
In the unlikely event of a refrigerant leak, shut-off valves isolate the affected zone while the remaining indoor units continue to operate.
The systems can be operated using a range of remote controllers, including a model with a dark mode. All controllers support the integrated safety management system.
In this way, the systems fully comply with the requirements of IEC 60335-2-40 and EN 378 – the main standards for the safe operation of systems with A2L class refrigerants.