Standard Inverter
  • PAM control
    PAM control

    PAM is a technology that controls the current waveform so that it resembles the supply voltage wave, thereby reducing loss and realising more efficient use of electricity. Using PAM control, 98% of the input power supply is used effectively.

  • Auto restart
    Auto restart

    Especially useful at the time of power outages, the unit turns back on automatically when power is restored.

  • Low temp cooling
    Low temp cooling

    Intelligent fan speed control in the outdoor unit ensures optimum performance even when the outside temperature is low.

  • On/Off Operation Timer
    On/Off Operation Timer

    Use the remote controller to set the times of turning the air conditioner On/Off.

  • Pure white
    Pure white

    Pure white is adopted for the unit color; white expressing the essence of cleanliness and easily matching virtually all interior decor.

  • M-NET Connection
    M-NET Connection

    Units can be connected to MELANS system controllers (M-NET controllers).

  • ACO
    ACO

    The air conditioner automatically switches between heating and cooling modes to maintain the desired temperature.

  • Flare connection
    Flare connection

    Flare connection to cooling pipework is possible.

  • Self Diagnostics
    Self Diagnostics

    Check codes are displayed on the remote controller or the operation indicator to inform the user of malfunctions detected.

  • Horizontal Vane Swing
    Horizontal Vane Swing

    The air outlet fin swings from side to side so that the airflow is spread evenly throughout the room.

  • Failure recall
    Failure recall

    Operation failures are recorded, allowing confirmation when needed.

  • Pump Down Switch
    Pump Down Switch

    Enables smooth and easy recovery of refrigerant.

  • System Group Control
    System Group Control

    The same remote controller is capable of controlling the operational status of up to 16 refrigerant systems.

  • Reuse of Existing Wiring
    Reuse of Existing Wiring

    The wiring method has been improved, making it possible to use methods different from that utilized for control and power supply.

  • COMPO
    COMPO

    Multiple indoor units can be connected to a single outdoor unit.

  • Low-noise Operation (Outdoor Unit)
    Low-noise Operation (Outdoor Unit)

    System operation can be adjusted to prioritise less noise from the outdoor unit over air conditioning performance.

  • DC Fan Motor
    DC Fan Motor

    A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor.

  • WiFi Interface
    WiFi Interface

    Interface enabling users to control air conditioners and check operating status via devices such as personal computers, tablets and smartphones.

  • Cleaning-free Pipe Reuse
    Cleaning-free Pipe Reuse

    It is possible to reuse the same piping. It allows cleaning-free renewal of air conditioning systems that use R22 or R410 refrigerant.

  • DC Inverter
    DC Inverter

    Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.

  • Grooved piping
    Grooved piping

    High-performance grooved piping is used in heat exchangers to in-crease the heat exchange area.

  • Filter Check Signal
    Filter Check Signal

    Air conditioner operating time is monitored, and the user is notified when filter maintenance is necessary.

  • Vector-Wave Eco Inverter
    Vector-Wave Eco Inverter

    This inverter monitors the varying compressor motor frequency and creates the most efficient waveform for the motor speed. As the result, operating efficiency in all speed ranges is improved, less power is used and annual electricity cost is reduced.

  • Reluctance DC Rotary Compressor
    Reluctance DC Rotary Compressor

    Powerful neodymium magnets are used in the rotor of the reluctance DC motor. More efficient operation is realised by strong magnetic and reluctance torques produced by the magnets.

  • Highly Efficient DC Scroll Compressor
    Highly Efficient DC Scroll Compressor

    Higher efficiency has been achieved by adding a frame compliance mechanism to the DC scroll compressor. The mechanism allows movement in the axial direction of the frame supporting the cradle scroll, thereby greatly reducing leakage and friction loss, and ensuring extremely high efficiency at all speeds.

  • Magnetic Flux Vector Sine Wave Drive
    Magnetic Flux Vector Sine Wave Drive

    This drive device is actually a microprocessor that converts the compressor motor’s electrical current waveform from a conventional waveform to a sine wave (180°conductance) to achieve higher efficiency by raising the motor winding utilisation ratio and reducing energy loss.

  • Demand Function (Onsite Adjustment)
    Demand Function (Onsite Adjustment)

    The demand function can be activated when the unit is equipped with a commercially available timer or an On/Off switch is added to the CNDM connector (option) on the control board of the outdoor unit. Energy consumption can be reduced up to 100% of the normal consumption according to the signal input from outside.

    [Example; Power Inverter Series]

    Limit energy consumption by changing the settings of SW7-1, SW2 and SW3 on the control board of the unit. The following settings are possible:

    SW7-1 SW2 SW3 Energy consumption

    ON

    OFF OFF 100 %
    ON OFF 75 %
    ON ON 50 %
    OFF ON 0 % (Stop)
    * PUHZ outdoor only
  • Long-life Filter
    Long-life Filter

    A special process for the entrapment surface improves the filtering effect, making the maintenance cycle longer than that of units equipped with conventional filters.

  • CE
    CE

Standard Inverter

Installation of this floor-standing series is easy and quick.
An excellent choice when there is a sudden need for an air conditioner to be installed.


  • Where to buy
Cooling capacity [kW] 3.7 - 9.4 - 10.6
Heating capacity [kW] 2.8 - 11.2 - 12.5
Total input in cooling [kW] 2.686
Total input in heating [kW] 3.246
SEER 5.5
SCOP 4.0
Energy Efficiency Class (cooling) A
Energy Efficiency Class (heating) A+
Dimensions indoor unit - H*W*L [mm] 1900 - 600 - 360
Dimensions outdoor unit - H*W*L [mm] 981 - 1050 - 330 (+40)
Weight indoor/outdoor unit [kg] 46/76
SPL [dB(A)] 45 - 49 - 51
Air volume [m3/min] 25 - 28 - 30
Power supply 230 V / 50Hz
Price of set (with VAT without installation) 9 809.00 BGN